Tandy Concrete · 32 MPa · QLD · EN 15804 +A2
| Module | Boundary | total | fossil | biogenic | luluc | GHG | Source |
|---|---|---|---|---|---|---|---|
| A1 | declared | 213 | 213 | -0.03 | 0.01 | 213 | p.9 |
| A2 | declared | 15.9 | 15.9 | 7.2e-3 | 0.01 | 15.9 | p.9 |
| A3 | declared | 3.3 | 3.3 | 3.7e-4 | 3.2e-4 | 3.3 | p.9 |
| A1-A3Product (raw supply, transport, manufacturing) | declared | 232 | 232 | -0.02 | 0.03 | 232 | p.9 |
| A4Transport to site | declared | 2.8 | 2.8 | 6.3e-4 | 1.3e-3 | 2.8 | p.9 |
| A5Installation | declared | 15.1 | 15.1 | 2.1e-4 | 1.8e-3 | 15.1 | p.9 |
| B1Use | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B2Maintenance | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B3Repair | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B4Replacement | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B5Refurbishment | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B6Operational energy | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B7Operational water | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| C1Deconstruction | declared | 4.5 | 4.5 | 4.6e-4 | 4.6e-4 | 4.5 | p.9 |
| C2Transport (EoL) | declared | 12.7 | 12.7 | 2.9e-3 | 5.7e-3 | 12.7 | p.9 |
| C3Waste processing | declared | 7.2 | 7.2 | -7.3e-4 | 7.4e-4 | 7.2 | p.9 |
| C4Disposal | declared | 4.4 | 4.4 | -1.4e-3 | 2.5e-3 | 4.4 | p.9 |
| DReuse/recovery/recycling (beyond system) | declared | -13.2 | -13.2 | -0.04 | -0.02 | -13.2 | p.9 |
n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.
A4-A5 ARE declared here (Scope: Cradle to gate with options, A4-A5, and modules C1-C4, D). B1-B7 are ND (not declared). The full +A2 core GWP family plus A4/A5/C1-C4/D all sit on a single results table (p.9), not split across pages. Dual EN 15804+A1 / CML GWP table on p.11 not captured (dataset standardises on +A2). GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding. GWP-GHG (p.12) equals GWP-total per module. Compressive strength class N32 (=32 MPa, 28 days); exposure class A2; declared unit mass 2352 kg/m3.
Extraction: Claude (multimodal) structured extraction; PDF text layer (pdftotext -layout) used to lock exact result tokens; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02