← All products

AN3220100Enhanced

Tandy Concrete · 32 MPa · QLD · EN 15804 +A2

Upfront carbon (A1–A3)
232 kg CO₂e / 1 cubic meter
Declared A1–C4 total
279 kg CO₂e(partial — excludes B1, B2, B3, B4, B5, B6, B7)
Module D (credit, beyond system)
-13.2 kg CO₂e

Declaration

Registration
HUB-5394
Programme operator
EPD Hub
Regional programme
Declared unit
1 cubic meter · 2352 kg
Compressive strength
32 MPa @ 28 d
Location
Australia (place of installation and use); manufactured at 21 Mackay Slade Point Road, Mackay, Queensland. Product- and factory-specific EPD, no grouping.
Standard
EN 15804:2012+A2:2019/AC:2021 and ISO 14025
LCIA method
EF 3.1
Published / valid to
2026-02-15 → 2031-02-14
Data period
FY25 (1 July 2024 to 30 June 2025)
Verification
External (third-party)
PCR
EPD Hub Core PCR v1.2 (24 Mar 2025); c-PCR: EN 16757 (concrete and concrete elements)

Per-module GWP (kg CO₂e / 1 cubic meter) — traceable to source

Open source EPD PDF ↗
ModuleBoundarytotalfossilbiogeniclulucGHGSource
A1declared213213-0.030.01213p.9
A2declared15.915.97.2e-30.0115.9p.9
A3declared3.33.33.7e-43.2e-43.3p.9
A1-A3Product (raw supply, transport, manufacturing)declared232232-0.020.03232p.9
A4Transport to sitedeclared2.82.86.3e-41.3e-32.8p.9
A5Installationdeclared15.115.12.1e-41.8e-315.1p.9
B1Usenot declaredn.d.n.d.n.d.n.d.n.d.
B2Maintenancenot declaredn.d.n.d.n.d.n.d.n.d.
B3Repairnot declaredn.d.n.d.n.d.n.d.n.d.
B4Replacementnot declaredn.d.n.d.n.d.n.d.n.d.
B5Refurbishmentnot declaredn.d.n.d.n.d.n.d.n.d.
B6Operational energynot declaredn.d.n.d.n.d.n.d.n.d.
B7Operational waternot declaredn.d.n.d.n.d.n.d.n.d.
C1Deconstructiondeclared4.54.54.6e-44.6e-44.5p.9
C2Transport (EoL)declared12.712.72.9e-35.7e-312.7p.9
C3Waste processingdeclared7.27.2-7.3e-47.4e-47.2p.9
C4Disposaldeclared4.44.4-1.4e-32.5e-34.4p.9
DReuse/recovery/recycling (beyond system)declared-13.2-13.2-0.04-0.02-13.2p.9

n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.

Extraction notes & caveats

A4-A5 ARE declared here (Scope: Cradle to gate with options, A4-A5, and modules C1-C4, D). B1-B7 are ND (not declared). The full +A2 core GWP family plus A4/A5/C1-C4/D all sit on a single results table (p.9), not split across pages. Dual EN 15804+A1 / CML GWP table on p.11 not captured (dataset standardises on +A2). GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding. GWP-GHG (p.12) equals GWP-total per module. Compressive strength class N32 (=32 MPa, 28 days); exposure class A2; declared unit mass 2352 kg/m3.

  • Source prints decimals with comma separator and a Unicode hyphen-minus (e.g. '‐1,32E+01'); raw tokens normalized to ASCII (dot decimal + '-') so value ≈ parseFloat(raw).
  • Product standards field (p.2) lists 'EN 206', but the product description (p.2) specifies AS1379:2007(2017); product.standard set to AS 1379:2007(2017) as the governing concrete spec.

Extraction: Claude (multimodal) structured extraction; PDF text layer (pdftotext -layout) used to lock exact result tokens; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02