← All products

ATILTS4020100Enhanced

Tandy Concrete · 40 MPa · QLD · EN 15804 +A2

Upfront carbon (A1–A3)
280 kg CO₂e / 1 cubic meter
Declared A1–C4 total
329 kg CO₂e(partial — excludes B1, B2, B3, B4, B5, B6, B7)
Module D (credit, beyond system)
-13.5 kg CO₂e

Declaration

Registration
HUB-5480
Programme operator
EPD Hub
Regional programme
Declared unit
1 cubic meter · 2408 kg
Compressive strength
40 MPa @ 28 d
Location
Mackay, Queensland, Australia (place of production, raw material origin, and installation/use all in Mackay)
Standard
EN 15804:2012+A2:2019/AC:2021 and ISO 14025
LCIA method
EF 3.1
Published / valid to
2026-02-20 → 2031-02-19
Data period
1st July 2024 to 30th June 2025 (FY25)
Verification
External (third-party)
PCR
EPD Hub Core PCR v1.2 (24 Mar 2025); c-PCR: EN 16757 (concrete and concrete elements)

Per-module GWP (kg CO₂e / 1 cubic meter) — traceable to source

Open source EPD PDF ↗
ModuleBoundarytotalfossilbiogeniclulucGHGSource
A1declared259259-0.030.02259p.9
A2declared17.717.78.3e-30.0117.7p.9
A3declared3.43.43.8e-43.3e-43.4p.9
A1-A3Product (raw supply, transport, manufacturing)declared280280-0.020.03280p.9
A4Transport to sitedeclared2.92.96.5e-41.3e-32.9p.9
A5Installationdeclared16.616.65.6e-51.9e-316.6p.9
B1Usenot declaredn.d.n.d.n.d.n.d.n.d.
B2Maintenancenot declaredn.d.n.d.n.d.n.d.n.d.
B3Repairnot declaredn.d.n.d.n.d.n.d.n.d.
B4Replacementnot declaredn.d.n.d.n.d.n.d.n.d.
B5Refurbishmentnot declaredn.d.n.d.n.d.n.d.n.d.
B6Operational energynot declaredn.d.n.d.n.d.n.d.n.d.
B7Operational waternot declaredn.d.n.d.n.d.n.d.n.d.
C1Deconstructiondeclared4.64.64.7e-44.7e-44.6p.9
C2Transport (EoL)declared13.013.02.9e-35.8e-313.0p.9
C3Waste processingdeclared7.47.4-7.5e-47.6e-47.4p.9
C4Disposaldeclared4.54.5-1.4e-32.6e-34.5p.9
DReuse/recovery/recycling (beyond system)declared-13.5-13.5-0.04-0.02-13.5p.9

n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.

Extraction notes & caveats

Cradle-to-gate with options: A1-A5, C1-C4 and D declared; B1-B7 not declared (ND in the System Boundary matrix, p.5). A1/A2/A3 reported individually and as an A1-A3 aggregate. GWP-total equals GWP-fossil to printed precision (biogenic and LULUC are negligible) and equals GWP-GHG per module within rounding. All core GWP indicators (total/fossil/biogenic/LULUC) are on a single page (p.9, columns A1-D); GWP-GHG on p.12. A dual EN 15804+A1 / CML GWP table also appears on p.11 (not captured; the dataset standardises on +A2). Source prints comma decimal separators (e.g. '2,59E+02'); raw tokens preserve the comma as-printed (validator normalises it) while the Unicode minus (U+2010) in negative tokens is normalised to ASCII '-'. GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding.

  • Product standard ambiguity: the 'Product standards' field (p.2) states EN 206, but the product description (p.2), quality-management section (p.3) and bibliography (p.7) reference AS 1379 (Australian standard). Recorded the explicit field value (EN 206).

Extraction: Claude (multimodal) structured extraction; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02