Tandy Concrete · 40 MPa · QLD · EN 15804 +A2
| Module | Boundary | total | fossil | biogenic | luluc | GHG | Source |
|---|---|---|---|---|---|---|---|
| A1 | declared | 259 | 259 | -0.03 | 0.02 | 259 | p.9 |
| A2 | declared | 17.7 | 17.7 | 8.3e-3 | 0.01 | 17.7 | p.9 |
| A3 | declared | 3.4 | 3.4 | 3.8e-4 | 3.3e-4 | 3.4 | p.9 |
| A1-A3Product (raw supply, transport, manufacturing) | declared | 280 | 280 | -0.02 | 0.03 | 280 | p.9 |
| A4Transport to site | declared | 2.9 | 2.9 | 6.5e-4 | 1.3e-3 | 2.9 | p.9 |
| A5Installation | declared | 16.6 | 16.6 | 5.6e-5 | 1.9e-3 | 16.6 | p.9 |
| B1Use | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B2Maintenance | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B3Repair | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B4Replacement | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B5Refurbishment | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B6Operational energy | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B7Operational water | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| C1Deconstruction | declared | 4.6 | 4.6 | 4.7e-4 | 4.7e-4 | 4.6 | p.9 |
| C2Transport (EoL) | declared | 13.0 | 13.0 | 2.9e-3 | 5.8e-3 | 13.0 | p.9 |
| C3Waste processing | declared | 7.4 | 7.4 | -7.5e-4 | 7.6e-4 | 7.4 | p.9 |
| C4Disposal | declared | 4.5 | 4.5 | -1.4e-3 | 2.6e-3 | 4.5 | p.9 |
| DReuse/recovery/recycling (beyond system) | declared | -13.5 | -13.5 | -0.04 | -0.02 | -13.5 | p.9 |
n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.
Cradle-to-gate with options: A1-A5, C1-C4 and D declared; B1-B7 not declared (ND in the System Boundary matrix, p.5). A1/A2/A3 reported individually and as an A1-A3 aggregate. GWP-total equals GWP-fossil to printed precision (biogenic and LULUC are negligible) and equals GWP-GHG per module within rounding. All core GWP indicators (total/fossil/biogenic/LULUC) are on a single page (p.9, columns A1-D); GWP-GHG on p.12. A dual EN 15804+A1 / CML GWP table also appears on p.11 (not captured; the dataset standardises on +A2). Source prints comma decimal separators (e.g. '2,59E+02'); raw tokens preserve the comma as-printed (validator normalises it) while the Unicode minus (U+2010) in negative tokens is normalised to ASCII '-'. GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding.
Extraction: Claude (multimodal) structured extraction; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02