← All products

CTILTS4020100Enhanced

Tandy Concrete · 40 MPa · QLD · EN 15804 +A2

Upfront carbon (A1–A3)
284 kg CO₂e / 1 cubic metre
Declared A1–C4 total
332 kg CO₂e(partial — excludes B1, B2, B3, B4, B5, B6, B7)
Module D (credit, beyond system)
-13.4 kg CO₂e

Declaration

Registration
HUB-5527
Programme operator
EPD Hub
Regional programme
Declared unit
1 cubic metre · 2388 kg
Compressive strength
40 MPa @ 28 d
Location
Production at 11 McIntosh Drive, Airlie Beach, Queensland; raw material origin and installation/use in Australia. Product- and factory-specific EPD.
Standard
EN 15804:2012+A2:2019/AC:2021 and ISO 14025
LCIA method
EF 3.1
Published / valid to
2026-02-25 → 2031-02-24
Data period
1 July 2024 to 30 June 2025 (FY25)
Verification
External (third-party)
PCR
EPD Hub Core PCR version 1.2 (24 Mar 2025); c-PCR: EN 16757 (concrete and concrete elements)

Per-module GWP (kg CO₂e / 1 cubic metre) — traceable to source

Open source EPD PDF ↗
ModuleBoundarytotalfossilbiogeniclulucGHGSource
A1declared254254-0.040.02254p.9
A2declared26.326.30.010.0226.3p.9
A3declared4.14.14.7e-43.5e-44.1p.9
A1-A3Product (raw supply, transport, manufacturing)declared284284-0.030.03284p.9
A4Transport to sitedeclared2.22.24.9e-49.8e-42.2p.9
A5Installationdeclared16.716.7-5.3e-52.1e-316.7p.9
B1Usenot declaredn.d.n.d.n.d.n.d.n.d.
B2Maintenancenot declaredn.d.n.d.n.d.n.d.n.d.
B3Repairnot declaredn.d.n.d.n.d.n.d.n.d.
B4Replacementnot declaredn.d.n.d.n.d.n.d.n.d.
B5Refurbishmentnot declaredn.d.n.d.n.d.n.d.n.d.
B6Operational energynot declaredn.d.n.d.n.d.n.d.n.d.
B7Operational waternot declaredn.d.n.d.n.d.n.d.n.d.
C1Deconstructiondeclared4.54.54.6e-44.7e-44.5p.9
C2Transport (EoL)declared12.912.92.9e-35.7e-312.9p.9
C3Waste processingdeclared7.37.3-7.5e-47.5e-47.3p.9
C4Disposaldeclared4.54.5-1.4e-32.6e-34.5p.9
DReuse/recovery/recycling (beyond system)declared-13.4-13.4-0.04-0.02-13.4p.9

n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.

Extraction notes & caveats

EPD Hub single-column layout (Tandy Concrete). Scope: cradle-to-gate with options A4-A5 and C1-C4, D. A1/A2/A3 reported individually plus an A1-A3 aggregate; A4-A5, C1-C4 and D declared; B1-B7 are ND (not declared). All core GWP results (A1 through D) sit on one wide table on p.9; GWP-GHG on p.12. A dual EN 15804+A1 / CML GWP table appears on p.11 (not captured; dataset standardises on +A2). Identities hold within source rounding: A1-A3 = A1+A2+A3 and GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc per module. Product name field is 'CTILTS4020100Enhanced'; described as 'Tandy 40MPa Tilt up concrete' (compressive strength class S40 -> 40 MPa, 28 days).

  • 'Product standards' field prints 'EN 206' while the product description and LCA bibliography reference AS 1379 (Specification and supply of concrete); product.standard records the printed field value.
  • Raw tokens preserve the source's comma decimal separator (e.g. '2,54E+02'); value fields are the parsed decimals.
  • GWP-GHG C3 prints 7,32E+00 whereas GWP-total C3 prints 7,31E+00 (source rounding).
  • A4 GWP-total (2,19E+00) is 0.01 above GWP-fossil (2,18E+00) + biogenic + luluc due to source rounding.

Extraction: Claude (multimodal) structured extraction; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02