Entire Concrete · 50 MPa · NSW · EN 15804 +A2
| Module | Boundary | total | fossil | biogenic | luluc | GHG | Source |
|---|---|---|---|---|---|---|---|
| A1 | declared | 270 | 270 | 0.10 | 0.04 | 270 | p.8 |
| A2 | declared | 36.1 | 36.1 | 7.4e-3 | 0.02 | 36.1 | p.8 |
| A3 | declared | 3.6 | 3.6 | 6.1e-4 | 3.0e-4 | 3.6 | p.8 |
| A1-A3Product (raw supply, transport, manufacturing) | declared | 310 | 309 | 0.11 | 0.06 | 309 | p.8 |
| A4Transport to site | declared | 2.9 | 2.9 | 6.6e-4 | 1.3e-3 | 2.9 | p.8 |
| A5Installation | declared | 17.5 | 17.4 | 4.1e-3 | 2.9e-3 | 17.4 | p.8 |
| B1Use | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B2Maintenance | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B3Repair | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B4Replacement | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B5Refurbishment | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B6Operational energy | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B7Operational water | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| C1Deconstruction | declared | 4.3 | 4.3 | 4.4e-4 | 4.4e-4 | 4.3 | p.8 |
| C2Transport (EoL) | declared | 12.2 | 12.2 | 2.8e-3 | 5.5e-3 | 12.2 | p.8 |
| C3Waste processing | declared | 7.0 | 7.0 | -7.1e-4 | 7.1e-4 | 7.0 | p.8 |
| C4Disposal | declared | 4.3 | 4.3 | -1.4e-3 | 2.4e-3 | 4.3 | p.8 |
| DReuse/recovery/recycling (beyond system) | declared | -11.7 | -11.7 | -0.04 | -0.02 | -11.7 | p.8 |
n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.
A1/A2/A3 reported individually plus an A1-A3 aggregate. A4 and A5 ARE declared here (Cradle to gate with options, A4-A5, C1-C4, D). B1-B7 are ND (not declared). C1-C4 and D declared. All core EN 15804+A2 GWP modules (A1-A3, A4, A5, C1-C4, D) are on a single results page (p.8); GWP-GHG on p.11. GWP-total A1-A3 prints 310 while GWP-fossil A1-A3 prints 309 despite identical printed A1/A2/A3 splits (270/36.1/3.65 sum to 309.75) — source rounding. A dual EN 15804+A1 / CML GWP table also appears on p.10 (not captured; dataset standardises on +A2). GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding. Strength 50 MPa derived from strength class N50 and product description 'characteristic strength of 50MPa'.
Extraction: Claude (multimodal) structured extraction; System Boundary matrix (p.4) reconciled against per-module results tables (p.8 core, p.11 GWP-GHG); validated with zod + GWP identity checks · confidence high · 2026-07-02