← All products

N40/20 Xencrete

Entire Concrete · 40 MPa · NSW · EN 15804 +A2

Upfront carbon (A1–A3)
273 kg CO₂e / 1 cubic meter
Declared A1–C4 total
321 kg CO₂e(partial — excludes B1, B2, B3, B4, B5, B6, B7)
Module D (credit, beyond system)
-11.9 kg CO₂e

Declaration

Registration
HUB-5991
Programme operator
EPD Hub
Regional programme
Declared unit
1 cubic meter · 2306 kg
Compressive strength
40 MPa @ 28 d
Location
Hunter Valley (Greater Newcastle region), NSW, Australia; production-weighted average of 2 sites: Cameron Park and Singleton
Standard
EN 15804:2012+A2:2019/AC:2021 and ISO 14025
LCIA method
EF 3.1
Published / valid to
2026-04-15 → 2031-04-14
Data period
1 Jan 2024 – 31 Dec 2024
Verification
External (third-party)
PCR
EPD Hub Core PCR version 1.2 (24 Mar 2025); c-PCR: EN 16757 (concrete and concrete elements)

Per-module GWP (kg CO₂e / 1 cubic meter) — traceable to source

Open source EPD PDF ↗
ModuleBoundarytotalfossilbiogeniclulucGHGSource
A1declared2352350.100.04235p.8
A2declared34.234.27.1e-30.0234.2p.8
A3declared3.73.76.2e-33.0e-43.7p.8
A1-A3Product (raw supply, transport, manufacturing)declared2732730.100.06273p.8
A4Transport to sitedeclared3.03.06.7e-41.3e-33.0p.8
A5Installationdeclared16.416.43.9e-32.7e-316.4p.8
B1Usenot declaredn.d.n.d.n.d.n.d.n.d.
B2Maintenancenot declaredn.d.n.d.n.d.n.d.n.d.
B3Repairnot declaredn.d.n.d.n.d.n.d.n.d.
B4Replacementnot declaredn.d.n.d.n.d.n.d.n.d.
B5Refurbishmentnot declaredn.d.n.d.n.d.n.d.n.d.
B6Operational energynot declaredn.d.n.d.n.d.n.d.n.d.
B7Operational waternot declaredn.d.n.d.n.d.n.d.n.d.
C1Deconstructiondeclared4.44.40.044.5e-44.4p.8
C2Transport (EoL)declared12.412.40.035.6e-312.4p.8
C3Waste processingdeclared7.17.1-7.2e-47.2e-47.1p.8
C4Disposaldeclared4.34.3-1.4e-32.5e-34.3p.8
DReuse/recovery/recycling (beyond system)declared-11.9-11.8-0.04-0.02-11.8p.8

n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.

Extraction notes & caveats

Scope: A1–A5, C1–C4 and D declared; B1–B7 are ND (not declared). Product stage reported both split (A1/A2/A3) and as an A1–A3 aggregate. Unlike sibling HUB-5210, A4 and A5 ARE declared here. Full core GWP family (total/fossil/biogenic/LULUC) and all core indicators occupy a single page (p.8) spanning A1 through D; GWP-GHG on p.11. A dual EN 15804+A1 CML table (p.10) is present but not captured (dataset standardises on +A2). Identity checks hold within source rounding: A1-A3 = A1+A2+A3, and GWP-total = fossil+biogenic+luluc per module (biogenic A1-A3 aggregate 1.03E-01 vs component sum 0.108 differ ~5% from rounding of small values, within validator absolute tolerance). Declared unit mass 2306 kg/m³; strength N40 = 40 MPa characteristic (AS 1379), 28 days.

  • Manufacturer field on p.2 printed garbled as 'Entire, Hunter Vallet=y, NSW, Australia'; company name taken from cover as 'Entire Concrete'.

Extraction: Claude (multimodal) structured extraction; System Boundary matrix reconciled against per-module results tables; validated with zod + GWP identity checks · confidence high · 2026-07-02