Aurora Construction Materials Epping Pty. Ltd. · 25 MPa · VIC · EN 15804 +A2
| Module | Boundary | total | fossil | biogenic | luluc | GHG | Source |
|---|---|---|---|---|---|---|---|
| A1 | declared | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | — |
| A2 | declared | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | — |
| A3 | declared | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | in A1–A3 | — |
| A1-A3Product (raw supply, transport, manufacturing) | declared | 140 | 140 | -0.24 | 0.01 | 139 | p.18 |
| A4Transport to site | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| A5Installation | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B1Use | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B2Maintenance | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B3Repair | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B4Replacement | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B5Refurbishment | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B6Operational energy | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| B7Operational water | not declared | n.d. | n.d. | n.d. | n.d. | n.d. | — |
| C1Deconstruction | declared | 12.0 | 12.0 | 8.0e-4 | 5.8e-6 | 12.0 | p.18 |
| C2Transport (EoL) | declared | 14.5 | 14.5 | 9.0e-4 | 6.9e-6 | 14.5 | p.18 |
| C3Waste processing | declared | 8.0 | 7.8 | 0.21 | 3.6e-6 | 7.8 | p.18 |
| C4Disposal | declared | 0.86 | 0.86 | 6.9e-5 | 4.2e-7 | 0.86 | p.18 |
| DReuse/recovery/recycling (beyond system) | declared | -9.8 | -9.8 | -0.02 | -1.5e-6 | -9.8 | p.18 |
n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.
Cradle-to-gate + end-of-life EPD: modules A1-A3, C1-C4, D declared; A4-A5 and B1-B7 are ND (not declared) per the System Boundary matrix (Table 2, p.7). GWP family taken from Table 10 (EN 15804+A2, AR2520, per m3, p.18): Core indicators (GWP-total/fossil/biogenic/luluc) and Additional indicator GWP-GHG. GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc holds per module within source rounding; GWP-biogenic A1-A3 is a genuine declared negative value (-2.40E-01), explained on p.6 as a negative biogenic term landing in A1-A3. A1-A3 GWP-total = 140 kg CO2e/m3. Not captured (by dataset convention on +A2): the EN 15804+A1 'GWP' single indicator (Table 12, p.20), the GWP-GHG (IPCC AR5) carbon-footprint indicator (p.18), and the alternative 100% recycling / 100% landfill end-of-life scenarios (Tables 13-14, p.21-22) — Table 10's C1-C4/D use the representative Victorian building-and-demolition end-of-life scenario. LCIA: EF 3.1 package, SimaPro v9.6.0.1.