← All products

Premix Concrete – S32MPa GreenCrete 70

Piave Premix Concrete Pty Ltd · 32 MPa · VIC · EN 15804 +A2

Upfront carbon (A1–A3)
134 kg CO₂e / 1m3 of Premix Concrete supplied to the client
Declared A1–C4 total
176 kg CO₂e(partial — excludes A4, A5, B1, B2, B3, B4, B5, B6, B7)
Module D (credit, beyond system)
-1.6 kg CO₂e

Declaration

Registration
EPD-IES-23043
Programme operator
The International EPD System
Regional programme
EPD Australasia Ltd
Declared unit
1m3 of Premix Concrete supplied to the client · 2373 kg
Compressive strength
32 MPa
Location
Victoria (Victorian metropolitan region); one product manufactured at one site
Standard
ISO 14025:2006 and EN 15804:2012+A2:2019/AC:2021
LCIA method
EF 3.1
Published / valid to
2025-03-31 → 2030-03-31
Data period
2022-01-01 to 2022-12-31
Verification
External (third-party)
PCR
PCR 2019:14 Construction Products, v1.3.4 (2024-04-30, valid until 2025-06-20); c-PCR: C-PCR-003 Concrete and concrete elements (2024-04-30); core PCR: EN 15804

Per-module GWP (kg CO₂e / 1m3 of Premix Concrete supplied to the client) — traceable to source

Open source EPD PDF ↗
ModuleBoundarytotalfossilbiogeniclulucGHGSource
A1declaredin A1–A3in A1–A3in A1–A3in A1–A3in A1–A3
A2declaredin A1–A3in A1–A3in A1–A3in A1–A3in A1–A3
A3declaredin A1–A3in A1–A3in A1–A3in A1–A3in A1–A3
A1-A3Product (raw supply, transport, manufacturing)declared13413400.02134p.11
A4Transport to sitenot declaredn.d.n.d.n.d.n.d.n.d.
A5Installationnot declaredn.d.n.d.n.d.n.d.n.d.
B1Usenot declaredn.d.n.d.n.d.n.d.n.d.
B2Maintenancenot declaredn.d.n.d.n.d.n.d.n.d.
B3Repairnot declaredn.d.n.d.n.d.n.d.n.d.
B4Replacementnot declaredn.d.n.d.n.d.n.d.n.d.
B5Refurbishmentnot declaredn.d.n.d.n.d.n.d.n.d.
B6Operational energynot declaredn.d.n.d.n.d.n.d.n.d.
B7Operational waternot declaredn.d.n.d.n.d.n.d.n.d.
C1Deconstructiondeclared5.75.705.6e-45.7p.11
C2Transport (EoL)declared21.621.64.3e-197.7e-321.6p.11
C3Waste processingdeclared12.512.501.3e-312.5p.11
C4Disposaldeclared2.32.301.3e-32.3p.11
DReuse/recovery/recycling (beyond system)declared-1.6-1.60-1.7e-4-1.6p.11

n.d. = not declared (unknown, not zero) · NR = not relevant · in A1–A3 = reported only inside the A1–A3 aggregate · Column headings: total / fossil / biogenic / luluc / GHG. Page links open the source EPD at the table the figure was read from.

Extraction notes & caveats

EN 15804+A2, cradle-to-gate + end-of-life + D. Declared modules: A1-A3 (aggregate only), C1, C2, C3, C4, D; A4-A5 and B1-B7 are ND (not declared). Per module, GWP-total = GWP-fossil + GWP-biogenic + GWP-luluc within source rounding (biogenic ~0). GWP-GHG equals GWP-total (biogenic negligible). A1-A3 GWP-total = 134 kg CO2e/m3. Core table heading reads 'EN 15804+A2, PEF'; body text confirms EF 3.1 characterisation. Printed PDF page numbers match physical PDF pages.

  • Results tables report only the A1-A3 aggregate (no A1/A2/A3 split); A1, A2, A3 set to aggregate_only although the System Boundary matrix declares them (x).
  • Registration number printed as 'EPD-IES-23043'; source PDF filename uses zero-padded 'EPD-IES-0023043'.
  • Compressive strength 32 MPa derived from the product name 'S32MPa'; no explicit compressive-strength field or evaluation age is printed (strength_eval_days = null).
  • GWP-biogenic C2 kept as printed 4.34E-19 (declared, effectively zero).

Extraction: Claude (multimodal) structured extraction: pdftotext -layout for full text plus page-image reads (Read) to verify the System Boundary matrix and per-module GWP results tables; boundary matrix reconciled against results tables; validated with zod + GWP identity checks. · confidence high · 2026-07-02